ChatterBank1 min ago
Bleed radiators, nothing happens
Answers
No best answer has yet been selected by Ollie24. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.This happened to me recently. Have you checked the pressure on the boiler?
I checked mine and it was low, so I filled it using the fill valve. Next thing my dog comes running downstairs and there is a loud loud hissing sound. The water was flying across the room from the radiator.
Try adjusting the boiler pressure if you can, but don't unscrew the rad valve completely like I did first.
If you have a vented system with an expansion tank in the loft then probably the ball valve has stuck causing the system to run low on water. If it is a pressurised system then refill to one bar, vent the rads refilling as you go.
Switch off the system when you vent the rads as otherwise this can draw in air and compound the problem. Once all rads are free of air the system may need balancing to force water to rads that do not work well. Open up both valves full on the radiators furthest away from the boiler and close down the hottest radiator valves nearest, on the valve that needs a spanner. This will even up the flow through all rads.
Related Questions
Sorry, we can't find any related questions. Try using the search bar at the top of the page to search for some keywords, or choose a topic and submit your own question.