Quizzes & Puzzles24 mins ago
3 bed re-wire - how many circuits?
2 Answers
We are having our 3 bed house with garage re-wired but each quote details different amount of circuits. What should I be looking for?
Answers
Best Answer
No best answer has yet been selected by ljscott. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.Hi if I was quoting for this mine would probably consist of the following circuits
1 First floor lights
2 Ground floor lights
3 smoke alarms
4 Cooker
5 Shower
6 Top Floor Ring Main
7 Ground Floor Ring Main
8 Radial Circuit in Kitchen (for fixed appliances)
9 Garage Radial Circuit.
But we all think differently, but I would ask for A Radial circuit in Kitchen for fridge/freezer,washing machine etc,these are connected to spur units and therefore permanently connected so don't need to be connected Via RCCD, eliminating risk of nuisance tripping, specially while you are on holiday.
Hope this of help,please say if you need more info, Ray
1 First floor lights
2 Ground floor lights
3 smoke alarms
4 Cooker
5 Shower
6 Top Floor Ring Main
7 Ground Floor Ring Main
8 Radial Circuit in Kitchen (for fixed appliances)
9 Garage Radial Circuit.
But we all think differently, but I would ask for A Radial circuit in Kitchen for fridge/freezer,washing machine etc,these are connected to spur units and therefore permanently connected so don't need to be connected Via RCCD, eliminating risk of nuisance tripping, specially while you are on holiday.
Hope this of help,please say if you need more info, Ray