textmum | 22:17 Sat 30th Sep 2006 | Home & Garden
4 Answers
as above, How do you top up a baillant 824e combi boiler, the manual doesnt seem to have instructions and the water pressure gauge is low.
Gravatar

Answers

1 to 4 of 4rss feed

Best Answer

No best answer has yet been selected by textmum. Once a best answer has been selected, it will be shown here.

For more on marking an answer as the "Best Answer", please visit our FAQ.
You need to look for the filling loop usually a silver braided flexible hose somewhere under or very close to the boiler, fixed to the pipes. One end should be attached to the cold feed & the other end fixed to the heating retun pipe. just attach the end that is hanging loose then turn on the valves at each end of the hose until the pressure reaches approx 1 bar then turn off the valve's & dissconect the hose again. the hose is only a temp filling device & should not be left permanently in position.
Question Author
Sadly this does not appear to have a filling loop like our previous boiler had.
The 824E has a built in filling loop if it is not visible when you look up from underneath the boiler then you may have to pull the flap down & it will be in front of the pump.
Question Author
Found it, thank you.