Quizzes & Puzzles1 min ago
Heating problem
7 Answers
I have an indirect heating system which was fitted about 15 yrs ago,the problem i have now is every time the heating is turned on the vent pipe in to the small tank in my loft runs full bore with hot water back in to the tank.any idears how i can stop this and why it is doing it would be very helpful.
thanks
thanks
Answers
Best Answer
No best answer has yet been selected by badwolf28. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.a possible problem is pipework layout, which may not be the answer in this case as presumably the system worked ok before or a blockage in the pipework causing it to send the water up the vent pipework. do you have a cylinder in the airing cupboard? if so get one of your fridge magnets and see if the magnet will stick to the pipework that feeds off the F&E tank above in the loft, where it joins the pipework that tees from this feed ,the pump pipework and the c/h pipework.the magnet wont stick usually but if the pipe is sludged up with crap/hard scale then the magnet will stick.a quick test to try.
if it sticks then its a drain down, cut out the blocked pipwork and replace
if it sticks then its a drain down, cut out the blocked pipwork and replace