Quizzes & Puzzles2 mins ago
fitting a n electric shower
3 Answers
do i need 10mm cable for my 9.5/shower
Answers
Best Answer
No best answer has yet been selected by PLATER1950. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.For showers rated above 8kW a minimum cable size of 10mm2 is strongly recommended
You can use this guide:
http://www.tlc-direct.co.uk/Technical/Charts/V oltageDrop.html
You can use this guide:
http://www.tlc-direct.co.uk/Technical/Charts/V oltageDrop.html
what matters is the distance from the consumer unit to the shower and the voltage drop along the cable. if the distance is short enough , quite easy in modern apartments but not in houses ,for the lower rated showers (7.5kw )then 6mm might do, but not for 9.5kw
the reality of it is that 10mm costs more but when ,not if your shower fails and you wish to replace it with one that is more powerful than 9.5kw you will save a lot of work by having used 10mm in the first instance
the reality of it is that 10mm costs more but when ,not if your shower fails and you wish to replace it with one that is more powerful than 9.5kw you will save a lot of work by having used 10mm in the first instance