Switch With A Neon Warning Light.
11 Answers
We have a small dressing room with 4 lights. My wife is always leaving the light on. So I thought I would fit a switch with a light on so we could tell if the light was on. I bought one but I cannot fit it. The old switch has a Comm with two brown wires and a L1 with one brown wire. The new switch has four holes, L in, L out, N in and N out. As all the wires are Brown I don’t know what to do. I’ve tried loads of combinations. One works the light and another works the neon!! Any contribution gratefully received. Happy Christmas everyone, Bramley.
Answers
Take a neutral wire from the room light down to the switch N in.... put the common brown into L in and the L1 brown into L out and it will work.
18:09 Sat 02nd Dec 2017
The switch you've bought is not designed for lighting use, it's for heavy current devices, such as washing machines powered from the ring-main. It's very difficult to do what you want to do, as neons need a neutral wire and most lighting switches don't have one at the switch end. I understand your problem as I've thought about doing the same thing with a loft light with a switch on the landing. If someone on here comes up with a solution I'll be cribbing it.
You could replace the switch with oe of these:
https:/ /www.sc rewfix. com/p/e lkay-ou tdoor-2 -wire-p ir-time r/57008
A bit (lot) expensive just to save electricity - it would detect someone going into the dressing-room and then keep the light on for the time you set up to 2 hours. The switch would have to be inside the dressing-room, though, so all round not a very good solution.
https:/
A bit (lot) expensive just to save electricity - it would detect someone going into the dressing-room and then keep the light on for the time you set up to 2 hours. The switch would have to be inside the dressing-room, though, so all round not a very good solution.