News1 min ago
Vokera Combi Boiler Faultfinder
2 Answers
I have a Vokera Linea 28 combi boiler. The problem is on the supply of hot water. When a hot tap is turned on the burner flame fluctuates continually from full flame to no flame. Any help would be most welcome.
PipN
PipN
Answers
Best Answer
No best answer has yet been selected by Pip N. Once a best answer has been selected, it will be shown here.
For more on marking an answer as the "Best Answer", please visit our FAQ.The boiler is designed to modulate like this. High flame to heat the water to temperature then small flame to maintain temperature. The temperature of the water is monitored by a sensor which modulates the the gas from small to large flame. The problem with yours is that the small flame burner pressure is'nt set, hence cutting off. This is something that only a corgi engineer can correct. Should only cost you a standard one hour service (although it only takes 5 minutes to do)
When the flame is off can you still here the fan running?
When the flame is off can you still here the fan running?
Related Questions